京ICP备13044552号 www.300.cn Beijing
The mass flow meter produced by our company can well solve the difficult to measure fluid problems, such as high temperature, low temperature, high pressure, high viscosity, small flow, large temperature and pressure fluctuations, user requirements, fast response time, high accuracy requirements and other actual measurement needs .
U shape coriolis mass flow meter
U-tube Coriolis flowmeter can measure the lowest temperature -200 ℃, such as the measurement of LNG. The highest temperature can reach 350 ℃, and the highest pressure can be measured at 100MPa.
The mass flowmeter consists of a sensor and a transmitter. The mass flow meter is equipped with digital signal processor (DSP) -based digital transmission equipment, and integrates digital closed-loop vibration control (DLC) signal processing, sensor calculation and diagnostic functions, and has high measurement accuracy and extensive capabilities. And excellent reliability for you. On-line node configuration, fault diagnosis and data logging can be performed directly through HART or PC via Modbus to communicate with the communicator. The flow meter will not only calculate the process volume flow, cumulative volume and component ratio. TS series flow meters can also provide mass flow, density and temperature online in real time.
Product introduction
Coriolis mass flow meters are the most accurate measuring method in the world. The Coriolis measuring principle is used in a wide range of different branches of industry, such as the life sciences, chemicals, petrochemicals, oil and gas, food, and- no less importantly - in custody transfer applications. Coriolis flowmeters can measure virtually all fluids: cleaning agents, solvents, fuels, crude oil, vegetable oils, animal fats, latex, silicon oils, alcohol, fruit solutions, toothpaste, vinegar, ketchup, mayonnaise, gases or liquefied gases.
The Sincerity DMF series U-shape is the standard high performance coriolis mass flowmeters for the process industry. The U shape bent tube meter offers superior performance and high accuracy in virtually any application. From process control in (petro) chemical applications to concentration measurements in the food and beverage industry to custody transfer filling and transport measurements in the oil and gas industry. Its high-end options also make the DMF-1 Series U-shape the optimum device for cryogenic media like Liquefied Natural Gas (LNG) with temperatures down to -200°C / -392°F as well as applications involving high operating temperatures (up to 350°C / 662°F) or pressures (up to 1000 barg / 14504 psig).
Each Coriolis flowmeter has one or more measuring tubes which an exciter causes to oscillate artificially. As soon as the fluid starts to flow in the measuring tube, additional twisting is imposed on this oscillation due to the fluid’s inertia. Two sensors detect this change of the tube oscillation in time and space as the “phase difference.” This difference is a direct measure of the mass flow.
In addition, the fluid density can also be determined from the oscillation frequency of the measuring tubes. The temperature of the measuring tube is also registered to compensate thermal influences. The process temperature derived from this is available as an additional output signal.
Coriolis flow measuring principle
Product introduction
Flow Range | See charts below |
Connection | ANSI, DIN, JIS, or Sanitary Tri-Clamp flanges, etc. ( Connections can be customized) |
Maximum Pressure | 16 bar (230 psi), [Optional 40 bar (580 psi), up to 1000 bar (14504 psi)] |
Body Material | 304 Stainless Steel |
Measuring Tube Material | 316 L SS, HC Hastelloy, 316L SS + PTFE, HC + PTFE, etc. ( materials can be customized) |
Process Temperature Range | |
Integrate Type | -50 to 15°C (-58 to 302°F) |
Remote Type (-R) | -50 to 35°C (-58 to 662°F) |
Ambient Temperature | -40 to 55°C (-40 to 131°F) |
Working Humidity | (5 to 95%) RH at 25°C (77°F) |
Flow Accuracy | 0.2/ 0.1/ 0.05% (Liquid), 0.5% (gas) |
Density measuring | |
Range | 0.2 to 3.0 g/cm3 |
Error | ± 0.002 g/cm3, ± 0.001 g/cm3 |
Repeatability | 0.001 g/cm3 |
Temperature Accuracy | ±1.0°C |
Protection | IP67 |
Approvals | ATEX, CE, ISO9001, ISO14001, OHSAS18001 |
Communications | RS485 (RTU Modbus), HART (-HART option) |
Pulse Output | 0 to 10 kHz |
Current Output | 4 to 20 mA |
Power Supply | 24VDC, 220VAC (universal power source option) |
Product introduction
We have our own patented touch screen transmitters with DSP core processor with faster data processing speed.
Traditional light sensing transmitters. This is the technology for us for the last generation. They have a disadvantage that they will be dis-functional under the strong light in the outdoors.
Waterproof & Explosion- proof threading hole.With explosion proof rate of ExdibIICT6Gb.
Can be customized according to customer requirements. When the use temperature exceeds 150 ℃, it is recommended to use the split type. The standard cable length is 1 meter.
We can customize the materials for you as your requirements, including SS316L, HC Hastelloy, SS 2205 steel, Titanium, etc.
4-20mA, 0-10KHz, Standard RS 485 communication protocol, HART
All interfaces can be customized according to special requirements, including national standard flanges / American standard flanges / German standard flanges / Japanese standard flanges / threaded interfaces / quick joints, etc.
OEM We support OEM lables. We can customize everything on lables for you, even for the inner software.
Choose your own customized coriolis flowmeters
Shape selection table
Model DMF-1 | Description | ||
1 | Suffix Code | Process Connection Size | Measuring Range |
S3 | 3mm | 0-40kg/h 0-4kg/h (For high viscosity fluids, gases, etc.) | |
S6 | 6mm | 0-100kg/h 0-10kg/h (For high viscosity fluids, gases, etc.) | |
S8 | 8mm | 0-200kg/h 0-20kg/h (For high viscosity fluids, gases, etc.) | |
U10 | 10mm | 0-500kg/h 0-50kg/h (For high viscosity fluids, gases, etc.) | |
U15 | 15mm | 0-1500kg/h 0-150kg/h (For high viscosity fluids, gases, etc.) | |
U20 | 20mm | 0-3000kg/h 0-300kg/h (For high viscosity fluids, gases, etc.) | |
U25 | 25mm | 0-10t/h 0-1t/h (For high viscosity fluids, gases, etc.) | |
U40 | 40mm | 0-20t/h 0-2t/h (For high viscosity fluids, gases, etc.) | |
U50 | 50mm | 0-30t/h 0-3t/h (For high viscosity fluids, gases, etc.) | |
U65 | 65mm | 0-50t/h 0-5t/h (For high viscosity fluids, gases, etc.) | |
U80 | 80mm | 0-100t/h 0-10th (For high viscosity fluids, gases, etc.) | |
U100 | 100mm | 0-150t/h 0-15t/h (For high viscosity fluids, gases, etc.) | |
U125 | 125mm | 0-200t/h 0-20t/h (For high viscosity fluids, gases, etc.) | |
U150 | 150mm | 0-500t/h 0-50th (For high viscosity fluids, gases, etc.) | |
U200 | 200mm | 0-700t/h 0-70t/h (For high viscosity fluids, gases, etc.) | |
U250 | 250mm | 0-800t/h 0-80th (For high viscosity fluids, gases, etc.) | |
2 | Code | Accuracy | |
A | 土0.50% | ||
N | 土0.20% | ||
M | 土0.15% | ||
H | 土0.10% | ||
3 | Code | Sensor Temperature (Above 250°C and below -50°C the transmitter are separated installation.) | |
A | - 50~150℃ | ||
B | -50~ 250℃ | ||
C | -50~ 350℃ | ||
D | -200~ 150℃ | ||
4 | Code | Pressure | |
16 | 1.6Mpa | ||
40 | 4.0Mpa | ||
XX | With customer specified pressure | ||
5 | Code | Material of wetted parts | |
A | Stainless Steel 316L | ||
C | Hastelloy C | ||
D | Inner Wall Surface with PTFE spray(Large size only) | ||
E | Special Order: With customer specified material | ||
6 | Code | Process Connection | |
F | Flange GB/T 9123.1-2000 ANSI Weld Neck Flanges-ANSI Bl 6.5 | ||
W | Ferrule type | ||
L | Threaded connection | ||
T | With customer specified flange | ||
7 | Code | Sensor Housing | |
A | Stainless Steel 304 | ||
B | Stainless Steel 316L | ||
8 | Code | Transmitter | |
A | Integrative Installation | ||
B | Seperate Installation(connector length),with holder | ||
9 | Code | Transmitter ambient temperature | |
A | -20~50C | ||
B | -41 ~ 80°C | ||
10 | Code | Transmitter output | |
A | 4-20mA (Instant flow rate/density) 0-10KHz( Instant flow pulse output ), RS485 Modbus RTU | ||
B | 4-20mA (Instant flow rate/density) 0-10KHz( Instant flow pulse output ), RS485 Modbus RTU,HART | ||
11 | Code | Testing Certificate | |
F | Factory, Factory certificate | ||
I | GB, Third party certificate | ||
12 | Code | Language | |
A | Chinese | ||
B | English | ||
13 | Code | Transmitter Housing | |
B | Diecasted aluminum alloy housing Wiring Hold Size: M2Ox1.5 | ||
C | Diecasted aluminum alloy housing Wiring Hold Sze: 1/2"NPT | ||
14 | Code | Explosion Prrof | |
A | Exd ib ll CT6 Gb | ||
15 | Code | Protection Grade | |
A | IP67 |
Choose your own customized coriolis flowmeters
Application | U-SHAPE | TRIANGLE TYPE | MICRO BEND V-HAPE |
Most common | CNG/ LNG/ LPG dispensers | High viscosity and high pressure application | |
Pipeline size | DN3-DN300 | DN10-DN25 | DN10-DN300 |
Minimum flow rate | 0-1kg/h | 0-1500kg/h | 0-1000kg/h |
Maximum flow rate | 0-1000t/h | 0-10t/h | 0-1000t/h |
Characteristics | Flow range calibrated can be compressed. The classic typical type with more than 30 years histroy.. | More popular with pipeline size bigger than dn80, with smaller size and lower pressure drop. Most suitable for high viscosity liquids. | More popular with cng/lpg/lng dispensers, with even smaller size with most advanced technology. |
Downloads